Test Setup

As usual we are testing with our Chroma programmable loads to fully load each rail to a specific amount. This is important to get truly accurate results and not merely approximate values. The tests are conducted in two different temperature environments. One is normal room temperature of 25-26°C, while the second environment goes from room temperature and increases steadily up to 50°C. Especially during the higher temperatures we will see how good the power supplies are and what they're really made of. Components inside will perform much worse at higher temperatures, but we expect any good quality PSU to deal with such test conditions without failing.

Note: If you would like to know more about our testing methodology, equipment, and environment, please read our PSU testing overview.

DC Outputs
PSU Load 3.3V 5V 12V1 12V2 Wattage
(All Rails)
10% 1.42A 1.78A 1.89A 1.89A 61.5W
20% 2.85A 3.56A 3.78A 3.78A 122.5W
50% 7.12A 8.90A 9.44A 9.44A 301.0W
80% 11.39A 14.24A 15.11A 15.11A 472.5W
100% 14.24A 17.79A 18.88A 18.88A 578.0W

3.3V DC Output


The 3.3V rails were stable during testing, as usual showing a constant drop under increasing load. At maximum loads, the 3.3V rail does go out of spec, regardless of temperature. However, the consistency of the rail outputs regardless of temperature and input voltage is surprising, with all four test results paralleling each other.

5.0V DC Output


Results with the 5V rail are similar to the 3.3V rail. All four test cases parallel each other, dropping steadily under increasing load. At about 90% load, the 5V rail falls out of spec. It is unlikely that most users will put anywhere near a 90% load on a 600W power supply, and provided you stay below 80% load on the 3.3V and 5V rails there shouldn't be any problems.

5Vsb Output



12V DC Output



By far the most important rails on any power supply are the 12V rails. Unlike the 3.3 and 5V rails, the Silver Power Blue Lightning delivers a good, stable output on the 12V rails regardless of load. Again, the 12V outputs are very similar regardless of input voltage or temperature, and both rails are also nearly identical.

Internals, Continued Efficiency and PFC
Comments Locked

33 Comments

View All Comments

  • Per Hansson - Monday, August 27, 2007 - link

    If you take a DMM and measure the power drop on the actual molex connectors, and not take the results directly from the Chroma how does it look then?

    I suspect you have an exponential increase in resistance which causes the Chroma to display incorrect voltage values... (Because of the cable length from the PSU's connectors and up to your load, including interface boards)

    Sincerely - Per Hansson
  • MrOblivious - Monday, August 27, 2007 - link

    Well that and if this really is a Solytech (Deer) it could just be a flaming hunk of crap.
  • Per Hansson - Monday, August 27, 2007 - link

    Yea, but the voltage resistance issue is something that has been the same for all PSU reviews here at Anand

    When you have this problem with all PSU's you need to realize there is something wrong with your testing equipment, sorry for being so blunt... (Especially since none of the other 2 big sites report the same)

    And yes, some scope readings for this DEER PSU sure would have been interesting (just to make sure to beat the dead horse a bit more)
  • Christoph Katzer - Tuesday, August 28, 2007 - link

    Strange though that the Zippy G1 has nearly the whole time close to to 12.0v. I have seen reports from the companies and they look similar (also the high efficiency) and thus I don't think the resistance will be a big issue.
  • MrOblivious - Tuesday, August 28, 2007 - link

    Are they using a Chroma as well for those test reports? Or are they reading directly at the connector without another interface like the spec calls for?

  • Christoph Katzer - Tuesday, August 28, 2007 - link

    "Every" company in Taiwan uses Chroma for their own evaluations.
  • Per Hansson - Tuesday, August 28, 2007 - link

    Christoph Katzer; The issue is of course not that you are using the Croma, it's a great unit; however, the way you use it will most likely result in incorrect voltage readings

    Due to the fact that the resistance in the cables loading the unit will most likely result in a exponential increase in resistance, therefore the results shown by the Chroma will be incorrect, and more incorrect as the load increases and the resistance exponentially increases...

    Just putting a multimeter on an unloaded Molex connector, or, directly on the molex connector you are loading (and not further down where the chroma reads the voltage) would quickly prove or disprove my theory
  • mindless1 - Thursday, August 30, 2007 - link

    You are correct, that a high enough current on too low a wire gauge does cause significant voltage drop, I have observed it many times myself particularly with some of the poorer PSU using 12V connectors with less than 18 ga. wires.

    However, similarly we can't just take the reading from an unused molex connector instead, as a PSU is spec'd to provide it's voltages at the load through the existing wiring harness. It is not necessary to try to evenly distribute that load across all the wire pairs in that harness as that is a practically impossible scenario for implementation running a system, so a bit of a derating factor is needed to appoximate the typical expected loads. IMO, a good start would be loading each supply wire at about 6A (not counting ground returns) up until the rating per rail is met, leaving some supply wires per rail unused when (sum of rail wires * 6A) > rated current per rail. Obviously some connectors and leads are more robust and necessary than others, for example a floppy connector should just be ignored while the 2 x n 12V CPU connector should always be used.
  • mindless1 - Thursday, August 30, 2007 - link

    I meant, high enough current on too high, too small a wire gauge.
  • JarredWalton - Tuesday, August 28, 2007 - link

    But wouldn't regular PC components drawing power from a PSU result in the same sort of increase in resistance? (Note: I'm not at all an electrician, so I could be wrong. Just asking a question.)